Configuration
You usually find the settings for the serial port under Services - Serial Utilities - Over IP.
There you need to define a configurationb as follows:
Device
rs232
Baudrate
Depending on the display board (usually 2400 for ALGE or 9600 for FDS MLED)
Data Bits
8
Stop Bits
1
Parity
None
Flow Control
None
Echo
off
Under General Tab set the following:
Mode
Client
Protocol
TCP
Destination Address
www.remoteredirect.com
Destination Port
Depending on your link, use number from Output side
Under Advanced Tab set the following:
Raw Mode
on
No leading zeros
off
Reconnect interval
30
Inactivity timeout
0
Serial timeout
empty
TCP Echo
off
Close connections
off
Connect on data
off
Keep alive time
0
Keep alive interval
0
Keep alive probes
0