Configuration

You usually find the settings for the serial port under Services - Serial Utilities - Over IP.

There you need to define a configurationb as follows:

Parameter
Value

Device

rs232

Baudrate

Depending on the display board (usually 2400 for ALGE or 9600 for FDS MLED)

Data Bits

8

Stop Bits

1

Parity

None

Flow Control

None

Echo

off

Under General Tab set the following:

Mode

Client

Protocol

TCP

Destination Address

links.remoteredirect.com (not www.remoteredirect.com, which only passes web traffic)

Destination Port

Depending on your link, use the port number from Output side

Under Advanced Tab set the following:

Raw Mode

on

No leading zeros

off

Reconnect interval

30

Inactivity timeout

0

Serial timeout

empty

TCP Echo

off

Close connections

off

Connect on data

off

Keep alive time

0

Keep alive interval

0

Keep alive probes

0